top of page

Stacking One-Way

4 Panel Stack Closed.PNG

<<<

<<<

<<<

Fixed

© Copyrights

Motor Side

Motor Measure.PNG

The motor is installed on the fixed side of the door unit in the next available stud bay.

The ideal allocation for the motor is 12 inches from stud to stud.

The minimum space allowed for the motor is 8 Inches.

Two 1-1/8 holes will be drilled through the stud wall and the jamb to allow the belt to travel from the stud bay into the door unit.

 

Motor Holes.PNG

Return Pulley Side

There is two pulley options with a one-way system depending on ​the clearance between the top of the panel and the head track, and what size belt is needed for the system.

Inline Pulleyv2.PNG

The inline return pulley is used when there is a minimum of 11/16" between the top of the panel and the head track. The lead panel will travel under the return pulley to the closed position. 

The inline pulley excepts only 3/8" belt and is typically used for systems under 20'.

 

The split-track pulley is used when there is less than 11/16" between the top of the panel and the head track, or the system needs 1/2" belt. 

The split-track pulley allows the lead panel to travel past the return pulley with it being notched between the two tracks and installed in track two. 

The split-track pulley excepts both 3/8" and 1/2" belt and is typically used with 1/2" belt on systems larger than 20' or systems with clearance issues. 

 

Standard Pulley.PNG

Motion Sensors

Both interior & exterior motion sensors will be installed in the middle of the lead panel protecting the close where the lead panel and the lock jamb meet. 

4 Panel Stack Closed.PNG

Touchscreen

On a one-way system, the touchscreen will be installed on the lock jamb side of the unit, so the user may quickly enter or exit after a command is given. 

The touchscreen fits in a standard triple gang box, approx. 60 inches from the finished floor.

4 Panel Stack Open.PNG

Power Requirements

The system requires a 110 Volt, 15 Amp dedicated circuit at the motor location.

The power supply plugs directly into a standard outlet.

powe-symbol-2.png

Home Automation Connection

All of our systems are compatible with major home automation brands.

The home automation connects through our dry contact adapter on the motor board.

The dry contact adapter comes standard with all of our systems for home automation integration.

images (1).png

Stacking One-Way

bottom of page